auxiliary pump product picture 4
Auxiliary coolant pump PAD2 FL
Auxiliary coolant pump PAD2 FL
Auxiliary coolant pump PAD2 FL
Auxiliary coolant pump PAD2 FL
  • IP Protection Class: IP6Kx, IPx6K, IPx7, IPx9K
  • Opening Angle: 150°
  • Range: <1 to 160m
  • Interface: CAN-FD, ROS2

Product Specification

Field of View

Specifications
Specifications
Field of View (FoV)
Distance measurement​

Horizontal range​

Vertical range​
0.23 m … 160 m

+/- 75°​

+/- 15°​
Specifications
Key-Performance Indicator​ (KPI)
Range precision
Separability

Velocity range / ​
- precision
- separability

Horizontal angle precision/
Separability

Vertical angle precision / Separability
0.09 m…0.12 m
0.45 m…0.47 m​

+/- 80 m/s
0.04 m/s…0.06 m/s
0.24 m/s​

0.1°
4.0°

0.2°
6.0°​​
Specifications
Interfaces & power
Data interface

Cycle time

Power consumption
CAN-FD ​(500/2000 kBit/s) ​

66 ms

<3 W
Specifications
Mechanics
Box volume
63 x 72 x 19 mm

The "Location Gateway Unit (LGU)" is the primary software interface of the radar sensor, through which all measurement data and associated system information are output.​

Up to 255 individual locations can be transmitted per measurement cycle. Each location represents a detected point within the sensor's detection range and is enriched with a set of specific metadata to allow for detailed interpretation of the measurement.​

Each location is transmitted as a separate data object and contains the following exemplary metadata (see table).​

In addition to the locations, the LGU continuously transmits other important status and system signals.​

Name​

Startbit​ Length​ [Bit] Factor​ Offset​ Minimum​ Maximum​ Unit​
Name​

RadialDistance​
Startbit​
32
Length​ [Bit]
15
Factor​
0.01
Offset​
0
Minimum​
0
Maximum​
327.67
Unit​
m
Name​

RadialVelocity​
Startbit​
47
Length​ [Bit]
15
Factor​
0.01
Offset​
-163.84
Minimum​
-110
Maximum​
55
Unit​
m/s
Name​

Elevation​
Startbit​
62
Length​ [Bit]
10
Factor​
0.1
Offset​
-51.2
Minimum​
-45
Maximum​
45
Unit​
deg
Name​

Azimuth​
Startbit​
72
Length​ [Bit]
11
Factor​
0.1
Offset​
-102.4
Minimum​
-90
Maximum​
90
Unit​
deg
Name​

DistVelocityCoVnce​
Startbit​
83
Length​ [Bit]
11
Factor​
0.0001
Offset​
-0.1024
Minimum​
-0.1024
Maximum​
0.1023
Unit​
m^2/s
Name​

RadialDistanceVnce​
Startbit​
94
Length​ [Bit]
10
Factor​
5,00E-05
Offset​
0
Minimum​
0
Maximum​
0.05115
Unit​
m^2
Name​

RadialVelocityVnce​
Startbit​
104
Length​ [Bit]
10
Factor​
0.0001
Offset​
0
Minimum​
0
Maximum​
0.1023
Unit​
m^2/s^2
Name​

ElevationVnce​
Startbit​
114
Length​ [Bit]
10
Factor​
0.001
Offset​
0
Minimum​
0
Maximum​
1.023
Unit​
deg^2
Name​

AzimuthVnce​
Startbit​
124
Length​ [Bit]
10
Factor​
0.001
Offset​
0
Minimum​
0
Maximum​
1.023
Unit​
deg^2
Name​

RadarCrossSection​
Startbit​
134
Length​ [Bit]
10
Factor​
0.2
Offset​
-102.4
Minimum​
-50
Maximum​
70
Unit​
dBsm
Name​

DistVelocityQuality​
Startbit​
144
Length​ [Bit]
8
Factor​
1
Offset​
0
Minimum​
0
Maximum​
255
Unit​
unitless
Name​

ElevationQuality​
Startbit​
152
Length​ [Bit]
8
Factor​
1
Offset​
0
Minimum​
0
Maximum​
255
Unit​
unitless
Name​

AzimuthQuality​
Startbit​
160
Length​ [Bit]
8
Factor​
1
Offset​
0
Minimum​
0
Maximum​
255
Unit​
unitless
Name​

RSSI​
Startbit​
168
Length​ [Bit]
10
Factor​
0.1
Offset​
0
Minimum​
0
Maximum​
100
Unit​
unitless
Name​

AzimuthalPartnerId​
Startbit​
178
Length​ [Bit]
10
Factor​
1
Offset​
0
Minimum​
0
Maximum​
1023
Unit​
unitless
Name​

MeasurementStatus​
Startbit​
188
Length​ [Bit]
4
Factor​
1
Offset​
0
Minimum​
0
Maximum​
15
Unit​
0

There is a ROS2 driver available for the multi purpose radar sensor:

Abmessungen

Please contact us for a 3D model

Connector

  • Connector: MCON® 1.2 connector
  • Keying: „A“, 8 pole
  • Harness (female): Tyco 1-1719393-1
Pin No. Pin Function Function Type
Pin No.
1
Pin Function
MP-2
Function Type
Multi-purpose Pin 2 (COM-L)
Pin No.
2
Pin Function
MP-1
Function Type
Multi-purpose Pin 1 (COM-H)
Pin No.
3
Pin Function
n. a.
Function Type
n. a.
Pin No.
4
Pin Function
n. a.
Function Type
n. a.
Pin No.
5
Pin Function
GND
Function Type
Sensor ground: connected to terminal 31
Pin No.
6
Pin Function
COM1-L
Function Type
Communication interface 1: Low signal
Pin No.
7
Pin Function
COM1-H
Function Type
Communication interface1: High signal
Pin No.
8
Pin Function
VBATT
Function Type
Supply voltage for sensor (terminal 15/30)